A storage administrator wants to do a tech refresh from a legacy EQL system to a new Dell EMC SC Series array. What is needed to correctly size the new array?
Correct Answer:B
https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices-dell-emc-4024-b
Sizing an SC Series array for performance requirements - pag.9)
What is a characteristic of single-tier Flash on Dell EMC SC Series arrays?
Correct Answer:D
What provides data analytics for Dell EMC Midrange storage?
Correct Answer:D
To which bus is the Dell EMC Unity 880F DPE connected?
Correct Answer:D
The DPE on 480/F, 680/F, and 880/F systems is internally connected to Bus 99 which is a separate bus than the first SAS expansion port that is connected to Bus 0. Therefore, the DPE is recognized by the system as Bus 99 Enclosure 0 while the first DAE connected to the first SAS expansion port would be Bus 0 Enclosure 0. This is different than X00/F, X50F, and 380/F systems. Furthermore, this means that the twenty-five drives in front of the DPE for 480/F, 680/F, and 880/F systems are internally recognized as Bus 99 Enclosure 0 Drive 0 – Bus 99 Enclosure 0 Drive 24. In Unisphere, the drives are seen DPE Drive 0 –DPE Drive 24
Which QoS options are supported by Dell EMC Unity XT?
Correct Answer:D
When designing a Dell EMC SC Series system, which factors regarding general performance are important to understand?
Correct Answer:C
"Whether gathering information or designing a system, it is important to understand two commonly used terms: Latency and queue depth"